Technical Data
| Description | Type B / B/2 |
Type C / C/2 |
Type R / R/2 |
Type D | Type E | |
|---|---|---|---|---|---|---|
| Moulding material | PBTP (Polyester) | |||||
| Flammability | UL 94 V-O | |||||
| Material contacts | Copper alloy | |||||
|
Clearance distance
|
||||||
|
Creeppage distance
|
Contact/ground | ... | ... | |||
| Contact/contact | ||||||
| Initial contact resistance | ||||||
| Initial insulation resistance |
Quality class 1 Quality class 2 Quality class 3 |
|||||
| Working voltage | 250 V | 125 V | ||||
|
depending on isolation coordination (refer to DIN VDE 0110/IEC 664-1) |
||||||
| Working current** click here for Derating diagrams |
+ 20° C | 2 A | 5,5 A | |||
| + 70° C | 1 A | 4 A | ||||
| + 100° | 0,5 A | 2,5 A | ||||
| Operating temperature | -55° C ... +125° C |
|||||
| Insulation group | A | C | ||||
| Test voltage V.r.m.s. | Contact/ground | 1550 V | 1550 V | |||
| Contact/contact | 1000 V | 1550 V | ||||
| Insertion and withdrawal forces [F max.] | 16 pos.
15 N 96 pos. 90 N |
16 pos. 20 N 32 pos. 40 N |
16 pos. 20 N 32 pos. 40 N 48 pos. 60 N |
|||
| Quality class | Quality class 3 =
50 mating cycles Quality class 2 = 400 mating cycles Quality class 1 = 500 mating cycles |
|||||