Technical Data

Description Type
B  /  B/2
Type
C  /  C/2
Type
R  /  R/2
Type D Type E
Moulding material PBTP (Polyester)
Flammability UL 94 V-O
Material contacts Copper alloy

Clearance distance   
Contact/contact

greater than or equal to 1,2 mm greater than or equal to 3 mm

Creeppage distance   
 

Contact/ground ... ...
Contact/contact greater than or equal to 1,2 mm greater than or equal to 3 mm
Initial contact resistance less than or equal to 20 mohms less than or equal to 15 m ohms
Initial insulation  resistance Quality class 1
Quality class 2
Quality class 3
greater than or equal to 1012
greater than or equal to 1012
greater than or equal to 1011
Working voltage 250 V 125 V

depending on isolation coordination (refer to DIN VDE 0110/IEC 664-1)

Working current**
click here for
Derating diagrams
+ 20° C 2 A 5,5 A
+ 70° C 1 A 4 A
+ 100° 0,5 A 2,5 A
Operating temperature -55° C
...
+125° C
Insulation group A C
Test voltage V.r.m.s. Contact/ground 1550 V 1550 V
Contact/contact 1000 V 1550 V
Insertion and withdrawal forces [F max.] 16 pos. 15 N
96 pos. 90 N
16 pos. 20 N
32 pos. 40 N
16 pos. 20 N
32 pos. 40 N
48 pos. 60 N
Quality class Quality class 3 =  50 mating cycles
Quality class 2 = 400 mating cycles
Quality class 1 = 500 mating cycles

 